Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.
thermal_layers.dz | [1.1, 1.1, 1.1, 1.1] |
thermal_layers.k | [0.602, 0.602, 0.602, 0.602] |
thermal_layers.rho_cp | [4170000, 4170000, 4170000, 4170000] |
Where: Legacy-format 2018a SUEWS_ESTMCoefficients.txt, code 813
Labels code 813 water other and stores four identical 1.1 m, 0.602 W m-1 K-1 and 4170000 J m-3 K-1 layer triplets.
Where: Pre-migration ESTM row 52240021
Preserves the same four-layer tuple, generic Water identity and dangling Ref 90240027.
| Name | supported Archived SUEWS 2018a water test fixture accurately identifies the retained legacy-format fixture row without presenting it as a physical water parameterization. |
|---|---|
| Target | supported The fixture labels code 813 !water, matching the land_cover.water target. |
| Values | supported The pinned legacy-format fixture code 813 stores four exact 1.1 m thickness, 0.602 conductivity and 4170000 volumetric heat-capacity triplets. These are configuration values, not measured water layers. |
| Source | supported Unreferenced is correct. No publication states or derives the selected four-layer tuple, and dangling legacy Ref 90240027 cannot be made into evidence. issue #297 |
| Place | supported The fixture's !water other row names no geographic study location, so generic is the supported place scope. |
| Representativeness | supported Generic records a preserved configuration artifact without asserting site, city or regional evidence. |
| Applicable Scale | supported Code 813 is a SUEWS water surface row, so its configuration applies to the water land-cover class. |
| Method | supported Assumed accurately records a retained test-fixture choice whose production is not documented as measured, fitted, calculated or literature-derived. |
| Identity | supported Legacy ID 52240021 and the exact four triplets establish the preserved fixture identity; stable path and Unknown origin remain unchanged. |
The exact tuple is configuration evidence, not a published water-layer parameterization. The pinned legacy-format fixture stores four 1.1/0.602/4170000 water-layer triplets under !water other. It is an archived legacy-format test fixture: the tagged SUEWS v2018a release input row has different thicknesses and heat capacity. Pre-migration database row 52240021 stores the same tuple and dangling Ref 90240027. The record therefore retains the exact fixture with source unreferenced, method assumed and source_legacy_ref 90240027; no value, stable path, origin or legacy ID changes.
Surf_thick5 | -999 |
Surf_k5 | -999 |
Surf_rhoCp5 | -999 |
Wall_thick1 | -999 |
Wall_k1 | -999 |
Wall_rhoCp1 | -999 |
Wall_thick2 | -999 |
Wall_k2 | -999 |
Wall_rhoCp2 | -999 |
Wall_thick3 | -999 |
Wall_k3 | -999 |
Wall_rhoCp3 | -999 |
Wall_thick4 | -999 |
Wall_k4 | -999 |
Wall_rhoCp4 | -999 |
Wall_thick5 | -999 |
Wall_k5 | -999 |
Wall_rhoCp5 | -999 |
Internal_thick1 | -999 |
Internal_k1 | -999 |
Internal_rhoCp1 | -999 |
Internal_thick2 | -999 |
Internal_k2 | -999 |
Internal_rhoCp2 | -999 |
Internal_thick3 | -999 |
Internal_k3 | -999 |
Internal_rhoCp3 | -999 |
Internal_thick4 | -999 |
Internal_k4 | -999 |
Internal_rhoCp4 | -999 |
Internal_thick5 | -999 |
Internal_k5 | -999 |
Internal_rhoCp5 | -999 |
nroom | -999 |
Internal_albedo | -999 |
Internal_emissivity | -999 |
Internal_CHwall | -999 |
Internal_CHroof | -999 |
Internal_CHbld | -999 |
Paste under land_cover.water in a SUEWS YAML configuration; every value carries its citation.
thermal_layers:
dz:
value:
- 1.1
- 1.1
- 1.1
- 1.1
ref:
ID: unreferenced
DOI: null
desc: generic, generic, land_cover
k:
value:
- 0.602
- 0.602
- 0.602
- 0.602
ref:
ID: unreferenced
DOI: null
desc: generic, generic, land_cover
rho_cp:
value:
- 4170000
- 4170000
- 4170000
- 4170000
ref:
ID: unreferenced
DOI: null
desc: generic, generic, land_cover
Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.
Review procedureland_cover.water · docs