Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.
holiday | 0.0323537821541511 0.0238330831422202 0.0192289696388521 0.01692690019212 0.0161873138200135 0.016385222240496 0.0184997630418287 0.0249267185622232 0.0345620124099515 0.0431349084681698 0.0468641404578933 0.0490829490523486 0.0509579633765945 0.0513537802175595 0.0454579607677079 0.0447287782587244 0.0491557923699122 0.0617285107009302 0.069270060406094 0.068728370084936 0.0636972021101098 0.0580722965043022 0.0523223505346436 0.0425411714882165 |
working_day | 0.0301041666666666 0.0215625 0.0183125 0.0170833333333333 0.0162916666666666 0.0174999999999999 0.0223749999999999 0.0370208333333333 0.0508541666666666 0.0443333333333333 0.0402708333333333 0.0386458333333333 0.0390625 0.0390625 0.0362083333333333 0.0378333333333333 0.0476041666666666 0.0679375 0.074875 0.0728125 0.0667083333333333 0.0630625 0.0565416666666666 0.0439375 |
Where: GreaterQFV3.2.7z/V3.2/Index2_EnergyHourly.csv, ElUNr_Wi rows 1-144
The public-release pointer records archive SHA-256 34ae31d1270068cd7b1ec277eab3e13a8ed0593e17589e0bf614bca5988f442d and size 30,435,425 bytes. The exact retained archive contains V3.2/Index2_EnergyHourly.csv, SHA-256 cbae41035e112e0d32805bf64d6ab9cfa7ae530f901f4ba4b4aaa866f791cde2. Its first, second and third 48-row ElUNr_Wi blocks are weekday, Saturday and Sunday profiles.
Where: GreaterQF v3.2 profile selection in Calcs3.py
Selects the weekday, Saturday or Sunday 48-row block and uses the domestic unrestricted column for domestic electricity and gas; UK public holidays are classified as Sundays.
Where: Section 2.1, Buildings, ERC load-reference profiles, p. 1758
States that 30-minute ERC domestic and industrial load-reference profiles cover weekdays, Saturday and Sunday at five times of year, and that domestic unrestricted electricity supplies the domestic gas profile as well as the sub-daily building-energy schedule.
Where: Table I, ERC/1 Buildings energy load profiles, p. 1756
Identifies the UK Energy Research Centre data portal as the source used by the model.
Where: UKERC/CEDA dataset 5af8ae29-86a7-4e8c-9fe4-1e2d99d9fb96
The authoritative Elexon dataset defines Profile Class 01 as Domestic Unrestricted and supplies half-hourly weekday, Saturday and Sunday profiles for the five seasons. The currently served rounded version does not numerically replace the exact GreaterQF v3.2 artifact used in this derivation.
Where: Historical database rows 60240940 and 60240942
Preserves the exact residential weekend and weekday vectors, the London identity and Ref 90240007 that resolves to Iamarino et al.; this is compilation lineage rather than proof that the paper prints the vectors.
| Name | supported The stable Iamarino name records the calculation lineage through the paper and the two pre-migration residential rows; it does not claim that the paper prints the final 24-hour vectors. |
|---|---|
| Target | supported Iamarino et al. use the ERC domestic unrestricted load profile as the sub-daily building-energy schedule, and the GreaterQF artifact labels the exact input column ElUNr_Wi. |
| Values | supported Adjacent pairs of the first 48 ElUNr_Wi values, divided by their total 48.000, reproduce the working-day vector exactly. Independently normalising the following Saturday and Sunday blocks, pairing their half-hours, and taking their equal mean reproduces the holiday vector exactly. |
| Source | supported The exact 24-hour outputs are a database calculation over GreaterQF input data, not numbers printed by Iamarino et al. The active source is therefore unreferenced; legacy Ref 90240007 is retained separately, while the sidecar records the paper, original Elexon dataset lineage and exact archived calculation artifact without crediting any of them with the derived output. issue #338 |
| Place | supported Both the article and the GreaterQF release identify London as the application domain. |
| Representativeness | supported The profile is used throughout the Greater London building-energy calculation, supporting city application scope rather than a single measurement site. |
| Method | supported Calculated records the deterministic half-hour pairing, within-day normalisation and equal Saturday-Sunday averaging that converts the archived 48-point inputs to the stored 24-point vectors. |
| Identity | supported Pre-migration rows 60240942 and 60240940 are respectively the London residential weekday and weekend entries named Iamarino; migration combines them as working_day and holiday without changing their order or values. |
other · working_day[h] = (Wd[2h] + Wd[2h+1]) / sum(Wd); holiday[h] = 0.5 * ((Sat[2h] + Sat[2h+1]) / sum(Sat) + (Sun[2h] + Sun[2h+1]) / sum(Sun)), for h = 0..23. · Aggregate adjacent half-hours from the GreaterQF winter domestic-unrestricted profiles; normalise each day type separately, and take an equal Saturday-Sunday mean for the holiday profile.
The scientific and numeric lineages are distinct. Iamarino et al. document that the London model uses UKERC domestic-unrestricted reference profiles, while Elexon/UKERC preserve the originating profile-class dataset and definitions. The exact higher-precision half-hour inputs used here survive in the GreaterQF v3.2 public-release archive. The deterministic calculation above reproduces both stored residential vectors, but no located publication prints those final 24 values. The record therefore moves from a misleading paper citation to an explicit unreferenced calculation, preserving Ref 90240007 only as historical metadata. Stable path, name, place, representativeness, values and legacy IDs are unchanged.
Paste under profile.energy-use in a SUEWS YAML configuration; every value carries its citation.
holiday: 1: 0.0323537821541511 2: 0.0238330831422202 3: 0.0192289696388521 4: 0.01692690019212 5: 0.0161873138200135 6: 0.016385222240496 7: 0.0184997630418287 8: 0.0249267185622232 9: 0.0345620124099515 10: 0.0431349084681698 11: 0.0468641404578933 12: 0.0490829490523486 13: 0.0509579633765945 14: 0.0513537802175595 15: 0.0454579607677079 16: 0.0447287782587244 17: 0.0491557923699122 18: 0.0617285107009302 19: 0.069270060406094 20: 0.068728370084936 21: 0.0636972021101098 22: 0.0580722965043022 23: 0.0523223505346436 24: 0.0425411714882165 working_day: 1: 0.0301041666666666 2: 0.0215625 3: 0.0183125 4: 0.0170833333333333 5: 0.0162916666666666 6: 0.0174999999999999 7: 0.0223749999999999 8: 0.0370208333333333 9: 0.0508541666666666 10: 0.0443333333333333 11: 0.0402708333333333 12: 0.0386458333333333 13: 0.0390625 14: 0.0390625 15: 0.0362083333333333 16: 0.0378333333333333 17: 0.0476041666666666 18: 0.0679375 19: 0.074875 20: 0.0728125 21: 0.0667083333333333 22: 0.0630625 23: 0.0565416666666666 24: 0.0439375
Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.
Review procedureprofile.energy-use · docsanthropogenic_emissions.heat.ahprof_24hr