SUEWS parameter database

curated values, linked and searchable, a citation on every one Home · Map · suews.io
browse · records/anthropogenic/london--ward2016.yml

Anthropogenic emissions — Central London evidence record

heat.qf_a.working_day0.3743
heat.qf_a.holiday0.3412
heat.qf_b.working_day0
heat.qf_b.holiday0
anthropogeniclondonsiteWard 2016

Parameters

Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.

heat.qf_a.working_day0.3743
heat.qf_a.holiday0.3412
heat.qf_b.working_day0
heat.qf_b.holiday0
heat.qf_c.working_day0.0073
heat.qf_c.holiday0.0067

Context

Conditions the set was derived under; not model inputs themselves.

context.qf_model2

Provenance evidence

Awaiting sign-off

Fitted · assessed by provenance-audit · 2026-09-01. Agent assessment is evidence preparation, not human verification.

Surface Urban Energy and Water Balance Scheme (SUEWS): Development and evaluation at two UK sitesParameter source

Where: Table 3, fitted central-London anthropogenic heat coefficients, p. 12

The Kc weekday/weekend columns publish 0.3743/0.3412, zero cooling terms, and 0.0073/0.0067 heating terms.

Assessment findings

Namesupported
The label identifies the published parameter class or model configuration.
Targetsupported
The source uses the parameter for the same SUEWS target represented by the record.
Valuessupported
The cited locator publishes the stored values at the available precision.
Sourcesupported
The cited source is a direct parameter publication or an explicit published model-input table.
Placesupported
The place agrees with the source scope or is explicitly generic.
Representativenesssupported
The record is classed site, matching the fitted coefficients for the central London Kc evaluation site; the publication does not establish city-wide evidence reach.
Methodsupported
The production or literature-compilation method is stated in the source.
Identitysupported
Stable path, target, source and values identify one retained database record.

Scientific note

Ward et al. fit the stored anthropogenic heat coefficients to the central London Kc data. The record is therefore classed site rather than city.

Legacy values (verbatim original columns; not SUEWS model inputs)

BaseT_HC18.2
AHMin_WD-999
AHMin_WE-999
AHSlope_Heating_WD-999
AHSlope_Heating_WE-999
AHSlope_Cooling_WD-999
AHSlope_Cooling_WE-999
TCritic_Heating_WD-999
TCritic_Heating_WE-999
TCritic_Cooling_WD-999
TCritic_Cooling_WE-999
MinQFMetab-999
MaxQFMetab-999
MinFCMetab-999
MaxFCMetab-999
FrPDDwe-999
FrFossilFuel_Heat-999
FrFossilFuel_NonHeat-999
EF_umolCO2perJ-999
EnEF_v_Jkm-999
FcEF_v_kgkmWD-999
FcEF_v_kgkmWE-999
CO2PointSource-999
TrafficUnits-999

Model-ready fragment

Paste under anthropogenic_emissions in a SUEWS YAML configuration; every value carries its citation.

heat:
  qf_a:
    working_day: 0.3743
    holiday: 0.3412
  qf_b:
    working_day: 0
    holiday: 0
  qf_c:
    working_day: 0.0073
    holiday: 0.0067

Evidence review

Awaiting sign-offSign off evidence on GitHub

Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.

Review procedure

Record metadata

Placelondon
Scopesite
Targetanthropogenic_emissions · docs
Origin“London, UK” (verbatim legacy string)
Schema2026.5 · legacy row 53240050

Same study, same place