SUEWS parameter database

curated values, linked and searchable, a citation on every one Home · Map · suews.io
browse · records/ohm/generic--ward2016--buildings--code-798-x-multiplier-for-winter-7982.yml

OHM coefficients — Code 798 x Multiplier for winter [7982] evidence record

a10.598
a20.337
a311.3
ohmLand-cover classWard 2016

Parameters

Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.

a10.598
a20.337
a311.3

Provenance evidence

Awaiting sign-off

Published value · assessed by provenance-audit · 2026-08-24. Agent assessment is evidence preparation, not human verification.

Surface Urban Energy and Water Balance Scheme (SUEWS): Development and evaluation at two UK sitesValidation

Where: Figure 8, seasonal-coefficient and constant-coefficient model results, p. 14

This is application and validation at London and Swindon, not the observation source for the triplet.

Rooftop average [798]Related record

Preserves the pre-adjustment code 798 coefficient set used by Ward's seasonal calculation; its evidence sidecar now records the component-wise mean of the three rooftop inputs.

Assessment findings

Namesupported
The companion table identifies code 7982 as code 798 multiplied for winter, with a2 unchanged.
Targetsupported
Ward et al. define these three values as coefficients in the OHM storage-heat equation.
Valuessupported
The exact code 7982 triplet 0.598, 0.337, 11.30 matches the stored values.
Sourcesupported
Ward et al. state the seasonal scaling and the companion v2016a table publishes the exact result.
Placenot applicable
Representativenessnot applicable
Applicable Scalesupported
Equation 6 weights the coefficients for each surface type by its surface cover fraction, and Table 4 lists this input as Bldgs, so the tuple describes the building land-cover class before neighborhood aggregation.
Methodsupported
The database adopts Ward's published output; Ward's authors produced it by scaling the compiled rooftop-average code rather than by a new observation or regression.
Identitysupported
The code, surface grouping and Winter season label agree with the v2016a table.

Scientific note

Ward et al. compile the pre-adjustment building coefficients as a mean of three study rows, then calculate seasonal a1 and a3 values using Anandakumar-derived multipliers. Their London and Swindon runs validate/apply the coefficients but are not their observation input. The separate code 798 input record now documents its calculated lineage from the three rooftop source-table rows.

Model-ready fragment

Paste under ohm_coefficients in a SUEWS YAML configuration; every value carries its citation.

a1:
  value: 0.598
  ref:
    ID: ward2016
    DOI: 10.1016/j.uclim.2016.05.001
    desc: land_cover
a2:
  value: 0.337
  ref:
    ID: ward2016
    DOI: 10.1016/j.uclim.2016.05.001
    desc: land_cover
a3:
  value: 11.3
  ref:
    ID: ward2016
    DOI: 10.1016/j.uclim.2016.05.001
    desc: land_cover

Evidence review

Awaiting sign-offSign off evidence on GitHub

Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.

Review procedure

Record metadata

Applicable scaleLand-cover class
Targetohm_coefficients · docs
SeasonWinter
Schema2026.5 · legacy row 50240026

Used by 2 typologies

Report an issue