SUEWS parameter database

curated values, linked and searchable, a citation on every one Home · Map · suews.io
browse · records/ohm/generic--unreferenced--buildings.yml

OHM coefficients — Rooftop average [798] evidence record unreferenced

a10.477
a20.337
a3-33.87
ohmFacet or componentunreferenced

Parameters

Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.

a10.477
a20.337
a3-33.87

Provenance evidence

Awaiting sign-off

Calculated · assessed by provenance-audit · 2026-08-24. Agent assessment is evidence preparation, not human verification.

Heat storage in Urban Areas: Local-Scale Observations and Evaluation of a Simple ModelInput observations

Where: Table 4, Rooftop rows for Vancouver, Uppsala and Kyoto, p. 932

The table gives the three exact parameter-labelled input rows, and the surrounding text states that coefficients within each surface category are averaged.

Surface Urban Energy and Water Balance Scheme (SUEWS): Development and evaluation at two UK sitesLater compilation

Where: Table 4, Bldgs row before adjustment for seasonal variation, p. 13

Where: Section 4.4, mean of values from three sites for building surfaces, p. 14

Where: SUEWS v2016a SUEWS_OHMCoefficients.txt, code 798

The article publishes the rounded building mean and describes its three-site calculation; the versioned companion table preserves the exact legacy tuple and code.

Assessment findings

Namesupported
Both publications describe a rooftop or building-surface average; neither supports the removed claim that this exact tuple was published in Grimmond et al. (1992).
Targetsupported
Both sources identify a1, a2 and a3 as OHM coefficients.
Valuessupported
The component-wise mean of 0.17/0.10/-17.0, 0.44/0.57/-28.9 and 0.82/0.34/-55.7 is 0.476666.../0.336666.../-33.866666..., which gives the stored 0.477/0.337/-33.87 after rounding.
Sourcenot applicable
This is an internal calculation from source-table inputs. Keeping source unreferenced avoids attributing the higher-precision calculated tuple to either publication.
Placenot applicable
Representativenessnot applicable
Applicable Scalesupported
Grimmond and Oke group all three inputs under the physical surface category Rooftop.
Methodsupported
Grimmond and Oke state that coefficients within each surface category are averaged, and Ward et al. explicitly say that the building coefficients use the mean of values from three sites.
Identitysupported
The versioned SUEWS v2016a table identifies the unchanged tuple as legacy code 798.

Derivation

arithmetic_mean · a1 = (yap-vancouver-a1 + taesler-uppsala-a1 + yoshida-kyoto-a1) / 3; a2 = (yap-vancouver-a2 + taesler-uppsala-a2 + yoshida-kyoto-a2) / 3; a3 = (yap-vancouver-a3 + taesler-uppsala-a3 + yoshida-kyoto-a3) / 3

Scientific note

The stable legacy code 798 record is a component-wise arithmetic mean of three rooftop rows, not a parameter tuple published by Grimmond et al. (1992). The source remains unreferenced because the exact stored precision is calculated; the sidecar records the source-table inputs without creating artificial atomic model records.

Model-ready fragment

Paste under ohm_coefficients in a SUEWS YAML configuration; every value carries its citation.

a1:
  value: 0.477
  ref:
    ID: unreferenced
    DOI: null
    desc: facet
a2:
  value: 0.337
  ref:
    ID: unreferenced
    DOI: null
    desc: facet
a3:
  value: -33.87
  ref:
    ID: unreferenced
    DOI: null
    desc: facet

Evidence review

Awaiting sign-offSign off evidence on GitHub

Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.

Review procedure

Record metadata

Sourceunreferenced — no citation was recorded in the legacy database; treat with care
Applicable scaleFacet or component
Targetohm_coefficients · docs
Schema2026.5 · legacy row 50240023
Report an issue