SUEWS parameter database

curated values, linked and searchable, a citation on every one Home · Map · suews.io
browse · records/constructions/gothenburg--bjork2002--traditional-neighbourhood-early-1900s.yml

Construction — Archived UMEP 4.4.3 Traditional Neighbourhood construction evidence record unreferenced

roof5 layers
roof_insulation_layer5
wall5 layers
wall_insulation_layer6
constructionsgothenburgcityunreferenced

Parameters

Repository-local construction fields; these are not direct SUEWS configuration parameters.

roof_insulation_layer
1-based position of the designated roof insulation layer in the construction, ordered from exterior to interior (1–5). Value 6 means no insulation layer is designated; it is not a sixth layer.
wall_insulation_layer
1-based position of the designated wall insulation layer in the construction, ordered from exterior to interior (1–5). Value 6 means no insulation layer is designated; it is not a sixth layer.

A designation does not verify the material type or the physical absence of insulation. These legacy selectors are not zero-based thermal-layer indices. UMEP preprocessing can use them to derive thermal inputs. Indexing, export behaviour and limitations.

Each facet lists its layers from the exterior (1) inward; thickness in metres. Follow a material for its thermal and radiative properties.

Roof

Layer (from exterior)MaterialThickness (m)
1Clay Tile Awaiting sign-off0.054
2Wood Awaiting sign-off0.025
3Waterproof roof covering Awaiting sign-off0.005
4Wood Awaiting sign-off0.025
5Air Awaiting sign-off insulation layer0.03

roof_insulation_layer = 5: layer 5 is the designated insulation layer.

Wall

Layer (from exterior)MaterialThickness (m)
1Wood Awaiting sign-off0.025
2Felt sheathing Awaiting sign-off0.001
3Wood Awaiting sign-off0.075
4Wood Awaiting sign-off0.025
5Plaster, dense Awaiting sign-off0.025

wall_insulation_layer = 6: no insulation layer is designated.

Insulation-layer selectors

roof_insulation_layer5
wall_insulation_layer6

Provenance evidence

Awaiting sign-off

Assumed · assessed by provenance-audit · 2026-08-25. Agent assessment is evidence preparation, not human verification.

SUEWS database pre-migration workbook: database.xlsxLater compilation

Where: Pre-migration Spartacus Surface row 37243437

Stores the exact roof and wall assembly, Gothenburg origin, wInsulation 6 and Ref 90242357. This establishes release and migration lineage, not publication support from Bjork.

Where: Official QGIS UMEP 4.4.3 release archive

The archive contains workbook SHA-256 50dfc15322115651f672fed86df1fdcc7dc8b13a58b7ced9b2e270b388aee6d3 with legacy row 37243437 set to wInsulation 6.

SUEWS database pre-migration workbook: database.xlsxValidation

Where: UMEP commit ee02726 and official 4.5 release

First public revision with row 37243437 wInsulation 2. The change is retained in UMEP 4.5 and later, but no commit message, issue, cell annotation or changelog explains its evidence basis.

Where: Official QGIS UMEP 4.5 release archive

Contains workbook SHA-256 53ba334067cbe51f98e42b3f6ee9544f2567184de9540a3982e05dbe3a690c81 with the same construction row set to wInsulation 2.

Assessment findings

Namesupported
The archival display name states the exact UMEP release identity selected by the maintainer and does not present the configuration as a construction verified from Bjork.
Targetsupported
The historical row defines roof and wall material assemblies and insulation indices, matching the construction target.
Valuessupported
The values are retained exactly as the migrated UMEP 4.4.3 configuration. In particular, wall_insulation_layer 6 means no designated wall-insulation layer; the later value 2 is documented as a release divergence rather than silently substituted.
Sourcesupported
Unreferenced is correct for the archived configuration because the Bjork source could not be inspected and no located publication establishes the complete assembly or insulation index. source_legacy_ref 90242357 preserves the migrated Bjork registry link without exporting it as proof.
issue #375
Placesupported
The historical row explicitly gives Origin Gothenburg, Sweden.
Representativenesssupported
City records the Gothenburg application identity of the archived row, not a claim that its physical assembly has been independently verified across the city.
Methodsupported
Assumed denotes the explicit curation decision to preserve the 4.4.3 release behavior while the later 4.5 change lacks a published rationale.
Identitysupported
Legacy ID 37243437 is continuous across both official artifacts. The stable record intentionally represents the migrated 4.4.3 snapshot, while the sidecar records that current UMEP uses value 2.

Scientific note

This is an identity and release-policy resolution, not a claim that value 6 is scientifically preferable to value 2. UMEP 4.4.3 and the database migration use 6, which makes the wall one horizontally aggregated layer. UMEP 4.5 and later use 2, which separates the 1 mm felt-sheathing layer during aggregation. Total material thickness and steady thermal resistance are unchanged, but transient storage behavior may differ. The maintainer chose to preserve historical 4.4.3 behavior; the record is therefore explicitly unreferenced and assumed, with the later release divergence retained as evidence rather than overwritten.

Construction record export

Local fields with citation wrappers. This is not a model-ready fragment: the exporter does not compile constructions into SUEWS thermal layers.

roof:
- material: records/materials/generic--unreferenced--clay-tile
  thickness:
    value: 0.054
    ref:
      ID: unreferenced
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--cibse2015--wood
  thickness:
    value: 0.025
    ref:
      ID: unreferenced
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--hertwig2024a--waterproof-roof-covering
  thickness:
    value: 0.005
    ref:
      ID: unreferenced
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--cibse2015--wood
  thickness:
    value: 0.025
    ref:
      ID: unreferenced
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--bellucco2017--air
  thickness:
    value: 0.03
    ref:
      ID: unreferenced
      DOI: null
      desc: gothenburg, city
roof_insulation_layer:
  value: 5
  ref:
    ID: unreferenced
    DOI: null
    desc: gothenburg, city
wall:
- material: records/materials/generic--cibse2015--wood
  thickness:
    value: 0.025
    ref:
      ID: unreferenced
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--hertwig2024a--felt-sheathing
  thickness:
    value: 0.001
    ref:
      ID: unreferenced
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--cibse2015--wood
  thickness:
    value: 0.075
    ref:
      ID: unreferenced
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--cibse2015--wood
  thickness:
    value: 0.025
    ref:
      ID: unreferenced
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--hertwig2024a--plaster-dense
  thickness:
    value: 0.025
    ref:
      ID: unreferenced
      DOI: null
      desc: gothenburg, city
wall_insulation_layer:
  value: 6
  ref:
    ID: unreferenced
    DOI: null
    desc: gothenburg, city

Evidence review

Awaiting sign-offSign off evidence on GitHub

Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.

Review procedure

Record metadata

Sourceunreferenced — no citation was recorded in the legacy database; treat with care
Scopecity
Reviewed scaleFacet typology · basis: stated in the record
Targetconstruction
Origin“Gothenburg, Sweden” (verbatim legacy string)
Schema2026.5 · legacy row 37243437

Used by 1 typology