Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.
thermal_layers.dz | [0.03, 0.12, 0.05] |
thermal_layers.k | [0.74, 0.93, 0.06] |
thermal_layers.rho_cp | [1900000, 1500000, 70000] |
Surf_thick4 | -999 |
Surf_k4 | -999 |
Surf_rhoCp4 | -999 |
Surf_thick5 | -999 |
Surf_k5 | -999 |
Surf_rhoCp5 | -999 |
Wall_thick1 | 0.1 |
Wall_k1 | 0.95 |
Wall_rhoCp1 | 1600000 |
Wall_thick2 | 0.1 |
Wall_k2 | 0.95 |
Wall_rhoCp2 | 1600000 |
Wall_thick3 | 0.1 |
Wall_k3 | 0.95 |
Wall_rhoCp3 | 1600000 |
Wall_thick4 | -999 |
Wall_k4 | -999 |
Wall_rhoCp4 | -999 |
Wall_thick5 | -999 |
Wall_k5 | -999 |
Wall_rhoCp5 | -999 |
Internal_thick1 | 0.05 |
Internal_k1 | 0.93 |
Internal_rhoCp1 | 1500000 |
Internal_thick2 | 0.05 |
Internal_k2 | 0.93 |
Internal_rhoCp2 | 1500000 |
Internal_thick3 | 0.05 |
Internal_k3 | 0.93 |
Internal_rhoCp3 | 1500000 |
Internal_thick4 | -999 |
Internal_k4 | -999 |
Internal_rhoCp4 | -999 |
Internal_thick5 | -999 |
Internal_k5 | -999 |
Internal_rhoCp5 | -999 |
nroom | 10 |
Internal_albedo | 0.2 |
Internal_emissivity | 1 |
Internal_CHwall | 0.001 |
Internal_CHroof | 0.001 |
Internal_CHbld | 0.001 |
Paste under land_cover.bldgs in a SUEWS YAML configuration; every value carries its citation.
thermal_layers:
dz:
value:
- 0.03
- 0.12
- 0.05
ref:
ID: offerle2005
DOI: 10.1002/joc.1198
desc: lodz, city
k:
value:
- 0.74
- 0.93
- 0.06
ref:
ID: offerle2005
DOI: 10.1002/joc.1198
desc: lodz, city
rho_cp:
value:
- 1900000
- 1500000
- 70000
ref:
ID: offerle2005
DOI: 10.1002/joc.1198
desc: lodz, city