Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.
a1 | 0.06 |
a2 | 0.28 |
a3 | -3 |
Where: Table 4, measured commercial/industrial bitumen roof — mixed wetness, wind 1.1-2.0 m s-1, p. 750
Four days of measurements on the UBC Music building; 0.06, 0.28 h, -3 W m-2.
Uses code 705 with six other Meyn rows and code 713 in its documented arithmetic mean.
| Name | supported Table 4 identifies a commercial or industrial bitumen roof under mixed wetness with wind 1.1-2.0 m s-1; code 705 is retained legacy identity. |
|---|---|
| Target | supported The source reports objective-hysteresis coefficients for roof heat storage. |
| Values | supported Table 4 states a1 0.06, a2 0.28 h and a3 -3 W m-2 exactly. |
| Source | supported Meyn and Oke directly publish the complete fitted tuple. |
| Place | supported The measured roof site is on the University of British Columbia campus in Vancouver. |
| Representativeness | supported The coefficients are derived from one monitored roof, supporting site scope. |
| Applicable Scale | supported Meyn and Oke fit each tuple to a specific monitored commercial/industrial or residential roof under the stated surface and weather condition, establishing roof-facet scale. issue #46 |
| Method | supported The table reports averages of regression coefficients fitted to hourly measured Q-star and roof conductive heat flux. |
| Identity | supported The material, wetness, wind class and exact tuple identify one Table 4 row; the related Helsinki record uses it as an arithmetic-mean input. |
The record is a direct, source-coherent transcription of one Table 4 regression row derived from measured fluxes. No canonical field changes.
Paste under ohm_coefficients in a SUEWS YAML configuration; every value carries its citation.
a1:
value: 0.06
ref:
ID: meyn2009
DOI: 10.1016/j.enbuild.2009.02.005
desc: vancouver, site, facet
a2:
value: 0.28
ref:
ID: meyn2009
DOI: 10.1016/j.enbuild.2009.02.005
desc: vancouver, site, facet
a3:
value: -3
ref:
ID: meyn2009
DOI: 10.1016/j.enbuild.2009.02.005
desc: vancouver, site, facet
Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.