SUEWS parameter database

curated values, linked and searchable, a citation on every one Home · Map · suews.io
browse · records/ohm/vancouver--grimmond1991b--buildings--roof-tar-and-gravel-summer-code-713.yml

OHM coefficients — Roof (tar and gravel, summer) [713] evidence record

a10.17
a20.1
a3-17
ohmvancouversiteFacet or componentGrimmond 1991

Parameters

Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.

a10.17
a20.1
a3-17

Provenance evidence

Awaiting sign-off

Fitted · assessed by provenance-audit · 2026-08-26. Agent assessment is evidence preparation, not human verification.

An objective urban heat storage model and its comparison with other schemesParameter source

Where: Table 1(a), development coefficients for OHM, rooftop — Vancouver, p. 314

Lists author Yap (1973) and coefficients a1 0.17, a2 0.10 h and a3 -17.0 W m-2.

This is the publication that performs and reports the OHM parameterisation.

Sensible heat fluxes measured in and near Vancouver, B.C.Input observations

Where: Figure 8, Vancouver School Board building site plan, p. 32

Labels the main experimental area and building roof as gravel and tar.

Establishes the physical observation surface and site, not the later OHM coefficients.

Sensible heat fluxes measured in and near Vancouver, B.C.Input observations

Where: Chapter 6, Urban Energy Balance, p. 131-158

Reports roof-top net-radiation and heat-storage observations used by the later OHM parameterisation.

Original observational lineage is kept distinct from the Grimmond et al. coefficient fit.

Roof (own for SMEAR III, Helsinki) [750]Related record

Uses code 713 with Meyn codes 701-707 in its documented eight-input arithmetic mean.

Assessment findings

Namesupported
Grimmond et al. identify the Vancouver summer rooftop row, while Yap's site plan identifies the observed Vancouver School Board surface as a gravel-and-tar roof. Code 713 is retained legacy identity.
Targetsupported
Table 1(a) presents the triplet as development coefficients for the Objective Hysteresis Model.
Valuessupported
Table 1(a) states 0.17, 0.10 h and -17.0 W m-2 exactly for the Vancouver rooftop row.
Sourcesupported
Grimmond et al. are the parameter publication that states the OHM fit. Yap's earlier thesis supplies the roof observations and must not be credited with coefficients it does not publish.
Placesupported
Both publications locate the rooftop observations in Vancouver, British Columbia.
Representativenesssupported
The observations concern the Vancouver School Board building roof, supporting site rather than city scope.
Applicable Scalesupported
The fitted tuple comes from the Vancouver School Board tar-and-gravel roof observations, so the described unit is the monitored roof facet.
issue #46
Methodsupported
Grimmond et al. present fitted OHM development coefficients derived from Yap's observational dataset.
Identitysupported
The exact tuple and Vancouver rooftop label identify one source row; the related Helsinki record uses this record as one of eight explicit arithmetic-mean inputs.

Scientific note

The canonical source remains Grimmond et al. (1991) because that paper states the fitted OHM tuple. Yap (1973) is now recorded separately as the original Vancouver gravel-and-tar roof observation source. This preserves the distinction between observations and parameter publication. No canonical value, place, scope, path or production method changes.

Model-ready fragment

Paste under ohm_coefficients in a SUEWS YAML configuration; every value carries its citation.

a1:
  value: 0.17
  ref:
    ID: grimmond1991b
    DOI: 10.1016/0957-1272(91)90003-W
    desc: vancouver, site, facet
a2:
  value: 0.1
  ref:
    ID: grimmond1991b
    DOI: 10.1016/0957-1272(91)90003-W
    desc: vancouver, site, facet
a3:
  value: -17
  ref:
    ID: grimmond1991b
    DOI: 10.1016/0957-1272(91)90003-W
    desc: vancouver, site, facet

Evidence review

Awaiting sign-offSign off evidence on GitHub

Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.

Review procedure

Record metadata

Scopesite
Applicable scaleFacet or component
Targetohm_coefficients · docs
Origin“Vancouver” (verbatim legacy string)
Schema2026.5
Report an issue