Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.
a1 | 0.64 |
a2 | 0.32 |
a3 | -43.6 |
Where: Section 3.1, Experimental data, p. 166-167
Locates the 1990-1991 pavement-slab experiment at Saitama University campus.
Where: Table I and least-squares method text, p. 174-175
Reports asphalt k1 = 0.64, k2 = 1142.16 s and k3 = -43.58 W m-2 and states that coefficients were fitted to hourly fluxes by least squares.
Where: Table 4, Asphalt — Asaeda and Ca (1993), p. 932
Repeats the rounded triplet 0.64, 0.32 h and -43.6 W m-2.
| Name | supported |
|---|---|
| Target | supported |
| Values | supported Asaeda and Ca Table I gives k1 = 0.64, k2 = 1142.16 s (0.3173 h) and k3 = -43.58 W m-2, which round to the stored 0.64, 0.32 and -43.6. |
| Source | supported |
| Place | supported |
| Representativeness | supported |
| Applicable Scale | supported Asaeda and Ca fit the tuple to a dry asphalt experimental pavement specimen, so the supported unit is the material rather than an area-weighted paved land-cover class. issue #46 |
| Method | supported |
| Identity | supported |
The primary article supplies the exact fitted values and method and locates the experiment at Saitama University campus. The stable record path is retained while the evidence envelope now records the site and site-scale representativeness explicitly.
Paste under ohm_coefficients in a SUEWS YAML configuration; every value carries its citation.
a1:
value: 0.64
ref:
ID: asaeda1993
DOI: 10.1007/BF00708822
desc: saitama-university, site, material
a2:
value: 0.32
ref:
ID: asaeda1993
DOI: 10.1007/BF00708822
desc: saitama-university, site, material
a3:
value: -43.6
ref:
ID: asaeda1993
DOI: 10.1007/BF00708822
desc: saitama-university, site, material
Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.