SUEWS parameter database

curated values, linked and searchable, a citation on every one Home · Map · suews.io
browse · records/materials/generic--unreferenced--glass-fibre-quilt.yml

Material — Glass-Fibre Quilt evidence record

thermal_conductivity0.04
specific_heat840
density12
materialsIntegrated Environmental Solutions Limited 2011

Parameters

Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.

thermal_conductivity0.04
specific_heat840
density12

Provenance evidence

Awaiting sign-off

Published value · assessed by provenance-audit · 2026-08-24. Agent assessment is evidence preparation, not human verification.

Apache-Tables User Guide: IES Virtual Environment 6.4Parameter source

Where: Table 6, System Material Database, Insulating Materials, Glass-Fibre Quilt row, p. 15

Reports conductivity 0.040 W/(m K), specific heat 840 J/(kg K), and density 12 kg/m3.

Assessment findings

Namesupported
Table 6 names the material Glass-Fibre Quilt exactly.
Targetsupported
Table 6 reports the three stored thermophysical material properties in their database units.
Valuessupported
The Glass-Fibre Quilt row reports thermal conductivity 0.040 W/(m K), specific heat 840 J/(kg K), and density 12 kg/m3, exactly the complete active tuple.
Sourcesupported
The official IES System Material Database table publishes every active value; the legacy Ref 99240099 was explicitly a missing-reference placeholder and is replaced by this source.
issue #273
Placenot applicable
Representativenessnot applicable
Methodsupported
Literature adoption is appropriate because the record takes an existing System Material Database row.
Identitysupported
Stable record path, name, legacy ID and all parameter values are preserved.

Scientific note

The historical workbook row and the IES table have an exact name-and-value match; this record has no optical fields, so the source supports the complete active parameter tuple.

Model-ready fragment

Paste under material in a SUEWS YAML configuration; every value carries its citation.

thermal_conductivity:
  value: 0.04
  ref:
    ID: ies2011-apache-tables
    DOI: null
    desc: null
specific_heat:
  value: 840
  ref:
    ID: ies2011-apache-tables
    DOI: null
    desc: null
density:
  value: 12
  ref:
    ID: ies2011-apache-tables
    DOI: null
    desc: null

Evidence review

Awaiting sign-offSign off evidence on GitHub

Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.

Review procedure

Record metadata

Targetmaterial