SUEWS parameter database

curated values, linked and searchable, a citation on every one Home · Map · suews.io
browse · records/materials/generic--hertwig2024a--plywood-heavyweight.yml

Material — Plywood (Heavyweight) evidence record

thermal_conductivity0.15
specific_heat1420
density700
materialsCIBSE 2015

Parameters

Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.

thermal_conductivity0.15
specific_heat1420
density700

Provenance evidence

Awaiting sign-off

Published value · assessed by provenance-audit · 2026-08-25. Agent assessment is evidence preparation, not human verification.

Guide A: Environmental designParameter source

Where: Table 3.38, plywood row, p. 3-43

Publishes plywood as density 700 kg m-3, thermal conductivity 0.15 W m-1 K-1 and specific heat 1420 J kg-1 K-1.

SUEWS database pre-migration workbook: database.xlsxLater compilation

Where: Pre-migration Spartacus Material row 36248182

Stores the same thermal tuple under MAPSECC Ref 90240069; the root spreadsheet contains the same row, excluding YAML migration as the cause of the attribution.

Assessment findings

Namesupported
Guide A names plywood; the retained Heavyweight qualifier preserves the legacy catalogue distinction.
Targetsupported
The source table and historical catalogue both describe thermophysical material properties.
Valuessupported
Table 3.38 publishes density 700 kg m-3, conductivity 0.15 W m-1 K-1 and specific heat 1420 J kg-1 K-1 for plywood, exactly matching the stored tuple.
Sourcesupported
CIBSE Guide A is the direct parameter source. The historical catalogue attributed this row to the MAPSECC dataset, but the MAPSECC author clarified that material values should cite CIBSE and that Hertwig et al. should be cited for the UK typologies instead.
issue #837
Placenot applicable
The generic material row makes no observation-place claim.
Representativenessnot applicable
The generic material row makes no site, city or regional evidence-reach claim.
Methodsupported
Literature denotes direct adoption of all three thermophysical values from Guide A.
Identitysupported
Legacy ID 36248182 identifies the retained catalogue row; correcting its source does not change the stable record path, its values or its material identity.

Scientific note

This correction changes provenance only: the complete stored tuple is an exact CIBSE Table 3.38 row. A repository-wide usage search finds this material unlinked from any current construction record. The stable record path remains unchanged because paths are database identities, not current citation labels.

Model-ready fragment

Paste under material in a SUEWS YAML configuration; every value carries its citation.

thermal_conductivity:
  value: 0.15
  ref:
    ID: cibse2015
    DOI: null
    desc: null
specific_heat:
  value: 1420
  ref:
    ID: cibse2015
    DOI: null
    desc: null
density:
  value: 700
  ref:
    ID: cibse2015
    DOI: null
    desc: null

Evidence review

Awaiting sign-offSign off evidence on GitHub

Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.

Review procedure

Record metadata

Targetmaterial
Schema2026.5 · legacy row 36248182