roof3 layers
roof_insulation_layer6
wall4 layers
wall_insulation_layer2
constructionsukregionalHertwig 2024a

Parameters

Repository-local construction fields; these are not direct SUEWS configuration parameters.

roof_insulation_layer
1-based position of the designated roof insulation layer in the construction, ordered from exterior to interior (1–5). Value 6 means no insulation layer is designated; it is not a sixth layer.
wall_insulation_layer
1-based position of the designated wall insulation layer in the construction, ordered from exterior to interior (1–5). Value 6 means no insulation layer is designated; it is not a sixth layer.

A designation does not verify the material type or the physical absence of insulation. These legacy selectors are not zero-based thermal-layer indices. UMEP preprocessing can use them to derive thermal inputs. Indexing, export behaviour and limitations.

Each facet lists its layers from the exterior (1) inward; thickness in metres. Follow a material for its thermal and radiative properties.

Roof

Layer (from exterior)MaterialThickness (m)
1Waterproof roof covering Awaiting sign-off0.0012
2Wood Wool Slab Awaiting sign-off0.02
3Plasterboard, standard Awaiting sign-off0.0125

roof_insulation_layer = 6: no insulation layer is designated.

Wall

Layer (from exterior)MaterialThickness (m)
1Brick, exposed Awaiting sign-off0.07
2Air Awaiting sign-off insulation layer0.05
3Brick, protected Awaiting sign-off0.07
4Plasterboard, standard Awaiting sign-off0.0125

wall_insulation_layer = 2: layer 2 is the designated insulation layer.

Insulation-layer selectors

roof_insulation_layer6
wall_insulation_layer2

Provenance evidence

Source inaccessible

assessed by provenance-audit · 2026-08-26. Agent assessment is evidence preparation, not human verification.

Multi-scale harmonisation Across Physical and Socio-Economic Characteristics of a City region (MAPSECC): London, UK [Data set]Later compilation

Where: MAPSECC Zenodo dataset record

The public record identifies the MAPSECC dataset, but the Materials source tables needed to verify the construction stacks are not available for inspection.

Assessment findings

Namesource inaccessible
The exact Materials source table and compilation mapping are unavailable, so this claim cannot be checked.
issue #213
Targetsupported
The source uses the parameter for the same SUEWS target represented by the record.
Valuessource inaccessible
The exact Materials source table and compilation mapping are unavailable, so this claim cannot be checked.
issue #213
Sourcesource inaccessible
The exact Materials source table and compilation mapping are unavailable, so this claim cannot be checked.
issue #213
Placesource inaccessible
The exact Materials source table and compilation mapping are unavailable, so this claim cannot be checked.
issue #213
Representativenesssource inaccessible
The exact Materials source table and compilation mapping are unavailable, so this claim cannot be checked.
issue #213
Methodsource inaccessible
The exact Materials source table and compilation mapping are unavailable, so this claim cannot be checked.
issue #213
Identitysupported
Stable path, target, source and values identify one retained database record.

Scientific note

The dataset identity and UK typology labels are known, but the exact layer stacks require embargoed/unavailable MAPSECC Materials files or an author locator. No stack value is altered.

Construction record export

Local fields with citation wrappers. This is not a model-ready fragment: the exporter does not compile constructions into SUEWS thermal layers.

roof:
- material: records/materials/generic--hertwig2024a--waterproof-roof-covering
  thickness:
    value: 0.0012
    ref:
      ID: hertwig2024a
      DOI: 10.5281/zenodo.12190341
      desc: uk, regional
- material: records/materials/generic--hertwig2024a--wood-wool-slab
  thickness:
    value: 0.02
    ref:
      ID: hertwig2024a
      DOI: 10.5281/zenodo.12190341
      desc: uk, regional
- material: records/materials/generic--hertwig2024a--plasterboard-standard
  thickness:
    value: 0.0125
    ref:
      ID: hertwig2024a
      DOI: 10.5281/zenodo.12190341
      desc: uk, regional
roof_insulation_layer:
  value: 6
  ref:
    ID: hertwig2024a
    DOI: 10.5281/zenodo.12190341
    desc: uk, regional
wall:
- material: records/materials/generic--hertwig2024a--brick-exposed
  thickness:
    value: 0.07
    ref:
      ID: hertwig2024a
      DOI: 10.5281/zenodo.12190341
      desc: uk, regional
- material: records/materials/generic--bellucco2017--air
  thickness:
    value: 0.05
    ref:
      ID: hertwig2024a
      DOI: 10.5281/zenodo.12190341
      desc: uk, regional
- material: records/materials/generic--hertwig2024a--brick-protected
  thickness:
    value: 0.07
    ref:
      ID: hertwig2024a
      DOI: 10.5281/zenodo.12190341
      desc: uk, regional
- material: records/materials/generic--hertwig2024a--plasterboard-standard
  thickness:
    value: 0.0125
    ref:
      ID: hertwig2024a
      DOI: 10.5281/zenodo.12190341
      desc: uk, regional
wall_insulation_layer:
  value: 2
  ref:
    ID: hertwig2024a
    DOI: 10.5281/zenodo.12190341
    desc: uk, regional

Evidence review

Source inaccessibleReview procedure

Record metadata

Placeuk
Scoperegional
Reviewed scaleFacet typology · basis: stated in the record
Targetconstruction
Origin“UK” (verbatim legacy string)
Schema2026.5 · legacy row 37240898
Report an issue