Names follow the SUEWS YAML specification; click one for its definition in the configuration reference.
roof | [{'material': 'records/materials/generic--unreferenced--roofing-felt', 'thickness': 0.01}, {'material': 'records/materials/generic--cibse2015--wood', 'thickness': 0.05}, {'material': 'records/materials/generic--unreferenced--plaster', 'thickness': 0.01}] |
roof_insulation_layer | 6 |
wall | [{'material': 'records/materials/generic--cibse2015--limestone-bright', 'thickness': 0.01}, {'material': 'records/materials/generic--hertwig2024a--brick-protected', 'thickness': 0.08}, {'material': 'records/materials/generic--unreferenced--plaster', 'thickness': 0.01}] |
wall_insulation_layer | 6 |
Where: Initial database.xlsx, Spartacus Surface row 37240892
The repository's root workbook (SHA-256 50dfc15322115651f672fed86df1fdcc7dc8b13a58b7ced9b2e270b388aee6d3) stores Sweden, Buildings, Industrial, all six material IDs and thicknesses, insulation index 6 for roof and wall, and placeholder Ref 99240099.
Where: Pre-migration Spartacus Surface row 37240892
The pinned row-for-row YAML transcript exposes the complete workbook assembly for line-level review immediately before record migration.
| Name | supported Archived Swedish industrial construction configuration identifies the retained catalogue assembly without presenting it as a published or physically validated construction recommendation. issue #266 |
|---|---|
| Target | supported Spartacus Surface row 37240892 stores roof and wall layer lists plus insulation-layer indices, matching the construction target. |
| Values | supported The initial workbook and its pinned migration transcript preserve all six material links, thicknesses 0.01/0.05/0.01 m for the roof and 0.01/0.08/0.01 m for the wall, and insulation index 6 for both. These facts support configuration identity only; component-material citations do not establish why the complete assembly was selected. |
| Source | supported Unreferenced is correct because no source supports the complete assembly. Ref 99240099 is the unreferenced placeholder, so it does not warrant a source_legacy_ref. The pinned workbook is compilation evidence for the archived configuration, not a parameter source. issue #266 |
| Place | supported Sweden is the explicit origin of workbook row 37240892. It identifies the intended application configuration, not a documented measurement site for the layer assembly. |
| Representativeness | supported Regional limits the catalogue entry to its labelled Swedish application scope. It does not assert that the complete assembly is empirically representative of Swedish industrial buildings. |
| Method | supported Assumed records the layer selection, thicknesses and insulation indices as retained configuration choices because no measurement, fit, calculation or literature derivation of the complete tuple was found. issue #266 |
| Identity | supported Legacy ID 37240892, Sweden origin, Industrial label and the exact two layer stacks establish a stable archived configuration identity from the repository's initial workbook through the migration. The stable path, origin and legacy ID remain unchanged. |
This record is retained solely as an archived internal Swedish industrial construction configuration, not as a recommended or evidence-backed physical assembly. The repository's initial database.xlsx contains the complete row before migration, and commit 053c004 preserves a field-for-field text transcript; the Swedish industry archetype continues to select the migrated record. No independent release/sample copy or publication for the complete assembly was found, and the component materials' citations cannot be composed into assembly provenance. Source therefore remains unreferenced and the configuration is classified as assumed. Placeholder Ref 99240099 is not promoted into source lineage. No material link, thickness, insulation index, stable path, origin or legacy ID is changed.
Paste under construction in a SUEWS YAML configuration; every value carries its citation.
roof:
- material: records/materials/generic--unreferenced--roofing-felt
thickness:
value: 0.01
ref:
ID: unreferenced
DOI: null
desc: sweden, regional
- material: records/materials/generic--cibse2015--wood
thickness:
value: 0.05
ref:
ID: unreferenced
DOI: null
desc: sweden, regional
- material: records/materials/generic--unreferenced--plaster
thickness:
value: 0.01
ref:
ID: unreferenced
DOI: null
desc: sweden, regional
roof_insulation_layer:
value: 6
ref:
ID: unreferenced
DOI: null
desc: sweden, regional
wall:
- material: records/materials/generic--cibse2015--limestone-bright
thickness:
value: 0.01
ref:
ID: unreferenced
DOI: null
desc: sweden, regional
- material: records/materials/generic--hertwig2024a--brick-protected
thickness:
value: 0.08
ref:
ID: unreferenced
DOI: null
desc: sweden, regional
- material: records/materials/generic--unreferenced--plaster
thickness:
value: 0.01
ref:
ID: unreferenced
DOI: null
desc: sweden, regional
wall_insulation_layer:
value: 6
ref:
ID: unreferenced
DOI: null
desc: sweden, regional
Raises a prefilled sign-off issue. CI accepts it only when the issue author is in the verifier registry and the evidence revision is still current.
Review procedureconstruction