SUEWS parameter database

curated values, linked and searchable, a citation on every one Home · Map · suews.io
browse · records/constructions/gothenburg--bjork2002--traditional-stone-neighbourhood-city-late-1800s-early-1900s.yml

Construction — Traditional Stone Neighbourhood City, late 1800s-early 1900s evidence record

roof3 layers
roof_insulation_layer6
wall4 layers
wall_insulation_layer6
constructionsgothenburgcityBjörk 2008

Parameters

Repository-local construction fields; these are not direct SUEWS configuration parameters.

roof_insulation_layer
1-based position of the designated roof insulation layer in the construction, ordered from exterior to interior (1–5). Value 6 means no insulation layer is designated; it is not a sixth layer.
wall_insulation_layer
1-based position of the designated wall insulation layer in the construction, ordered from exterior to interior (1–5). Value 6 means no insulation layer is designated; it is not a sixth layer.

A designation does not verify the material type or the physical absence of insulation. These legacy selectors are not zero-based thermal-layer indices. UMEP preprocessing can use them to derive thermal inputs. Indexing, export behaviour and limitations.

Each facet lists its layers from the exterior (1) inward; thickness in metres. Follow a material for its thermal and radiative properties.

Roof

Layer (from exterior)MaterialThickness (m)
1steel Awaiting sign-off0.01
2Roofing Felt Awaiting sign-off0.01
3Wood Awaiting sign-off0.025

roof_insulation_layer = 6: no insulation layer is designated.

Wall

Layer (from exterior)MaterialThickness (m)
1external render (lime, sand) Awaiting sign-off0.01
2Brick, protected Awaiting sign-off0.29
3Wood Awaiting sign-off0.025
4Plaster, dense Awaiting sign-off0.01

wall_insulation_layer = 6: no insulation layer is designated.

Insulation-layer selectors

roof_insulation_layer6
wall_insulation_layer6

Provenance evidence

Source inaccessible

assessed by provenance-audit · 2026-08-26. Agent assessment is evidence preparation, not human verification.

Så byggdes husen 1880-2000. Arkitektur, konstruktion och material i våra flerbostadshus under 120 årValidation

Where: LIBRIS catalogue record for the cited book

Establishes the book identity and its multi-family-housing scope, but not the stored construction layers.

Assessment findings

Namesource inaccessible
The exact edition pages and construction table were not available, so the stored stack cannot be verified.
issue #374
Targetsupported
The source uses the parameter for the same SUEWS target represented by the record.
Valuessource inaccessible
The exact edition pages and construction table were not available, so the stored stack cannot be verified.
issue #374
Sourcesource inaccessible
The exact edition pages and construction table were not available, so the stored stack cannot be verified.
issue #374
Placesource inaccessible
The exact edition pages and construction table were not available, so the stored stack cannot be verified.
issue #374
Representativenesssource inaccessible
The exact edition pages and construction table were not available, so the stored stack cannot be verified.
issue #374
Methodsource inaccessible
The exact edition pages and construction table were not available, so the stored stack cannot be verified.
issue #374
Identitysupported
Stable path, target, source and values identify one retained database record.

Scientific note

Public catalogues confirm the book but not the exact construction stack. The edition/full-text request remains optional for publication, but this evidence record cannot be signed off without the relevant pages.

Construction record export

Local fields with citation wrappers. This is not a model-ready fragment: the exporter does not compile constructions into SUEWS thermal layers.

roof:
- material: records/materials/generic--hertwig2024a--steel
  thickness:
    value: 0.01
    ref:
      ID: bjork2002
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--unreferenced--roofing-felt
  thickness:
    value: 0.01
    ref:
      ID: bjork2002
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--cibse2015--wood
  thickness:
    value: 0.025
    ref:
      ID: bjork2002
      DOI: null
      desc: gothenburg, city
roof_insulation_layer:
  value: 6
  ref:
    ID: bjork2002
    DOI: null
    desc: gothenburg, city
wall:
- material: records/materials/generic--hertwig2024a--external-render-lime-sand
  thickness:
    value: 0.01
    ref:
      ID: bjork2002
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--hertwig2024a--brick-protected
  thickness:
    value: 0.29
    ref:
      ID: bjork2002
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--cibse2015--wood
  thickness:
    value: 0.025
    ref:
      ID: bjork2002
      DOI: null
      desc: gothenburg, city
- material: records/materials/generic--hertwig2024a--plaster-dense
  thickness:
    value: 0.01
    ref:
      ID: bjork2002
      DOI: null
      desc: gothenburg, city
wall_insulation_layer:
  value: 6
  ref:
    ID: bjork2002
    DOI: null
    desc: gothenburg, city

Evidence review

Source inaccessibleReview procedure

Record metadata

Scopecity
Reviewed scaleFacet typology · basis: stated in the record
Targetconstruction
Origin“Gothenburg, Sweden” (verbatim legacy string)
Schema2026.5 · legacy row 37259482

Used by 2 typologies

Report an issue